Optical radiation sensors

General description:

Solar and sky radiation:

The spectral range spans over shorter wave lengths at 300 nm 
(UV-B) to longer wave length at 5000 nm (IR). 
The solar and sky radiation is the complete direct or 
diffuse sun radiation striking the earth’s surface.

UVA-radiation:

The UV-radiation of longer wave length (more than 313 nm) reaches the earth’s surface almost unfiltered, browns the human skin and enforces the immune system. In solariums the biological effect of the UVA-spectrum combined with other spectral ranges is used to take advantage of the direct pigmenting (melanin colouring). However, radiation which is too strong will harm the connective tissue and supports aging of the skin.

UVB-radiation:
The UV-range of short wave lengths (below 313 nm) can cause irreversible defects to human skin, summarized in the recommendation of the CIE. The UV-index is a popular measure for the sunburn-sensitivity. Directly or compared to other spectral ranges, the measured values inform about biologically and medically relevant relationships. 

Technical data for FL A613:
Operating temperature:  – 20 to + 60°C
Signal output:  0 V to 2 V
Power supply: + 7 V to + 15 V
Fastening: 2 screws M4 in ground plate
Diffusor: PTFE
Cos-correction: error f2 < 3 %
Linearity: < 1 %
Absolute error: < 10 %
Connection cable: length 1.5 m with ALMEMOŽ-connector

 

Order No.     Description
FL A613 GS      Measuring range: sky and sun, 0-1200 W/m2
                           Spectral sensitivity: 400 -1100 nm
                           Max. spectral sensitivity: 780 nm
                           Dome: PMMA
                           Residual voltage (E=0): < 10 mV
FL A613 UVA   Measuring range: UVA, 0-3 mW/cm2
                           Spectral sensitivity: 310 - 400 nm
                           Max. spectral sensitivity: 335 nm
                           Dome: PMMA, UV-perm.
                           Residual voltage (E=0): < 10 mV
FL A613 UVB   Measuring range: UVB, 0 - 50 mW/cm2
                           Spectral sensitivity: 265 - 315 nm
                           Max. spectral sensitivity: 297 nm
                           Dome: PMMA, UV-perm.
                           Residual voltage (E=0): < 50 mV

 

{Back}