TachometerFua9192.GIF (1469 bytes)

General description:
Optical tachometer with frequency module for photometric detection of rotational speed or triggering signals.

Application:
The movable part is equipped with a reflecting tape and the sensor is focussed to it. As a function control a yellow signal lamp lights up at the rear side of the instrument, when the reflecting foil is detected.

 

Specification for FU 1919 2
Measuring range: 8 to 10000 rpm,
higher speed on demand
Accuracy: ± 0,02 % of final value ± 1 digit
Resolution: ±1 rpm (± 1 digit)
Operation range: 20 to 200 mm (depending on reflector size)
Reference value: standard white 200 x 200 mm
Setting of detection range:  by means of potentiometer
Detectable object: opaque to light
Hysteresis of distance: £ 10 %
Type of light: red light 6600 nm
Limit of external light:  sun ligth £ 20000 Lux,
halogen light £ 5000 Lux
Ambiant temperature: – 25 to + 55 °C
Storage temperature: – 40 to + 70 °C
No-load current:  £ 20 mA
System of protection:  IP 67
Optics: 2-lense system PC
Allowed strain of shock: b £ 30 g, T £ 1 ms
Allowed strain of swing: f £ 55 Hz, a £ 1 mm
Connection cable: PVC (4 x 0,14 mm2) length 1,5 m,
ALMEMO®-connector
Housing: brass, nickeled
Outlet of light:  PMMA
Weight:  15 g
Power supply: 12 V obligatory
Conformity to standards: EN 60 947-5-2
Dimensions:  Ų M12x1 mm, length 55 mm

 

Order No. Description
FU A919 2 Optical tachometer incl. reflecting tape

 

{Back}