ALMEMO® measuring ranges

Type de capteur Type Plage de mesure Unité Résolution Préc. de linéarisation Fiche progr.
Temperature:
Pt100-1 4-wire FP Axxx -200.0 . +850.0 °C 0.1 K ± 0,05 K ± 0,05 % de v.m. ZA 9030-FS1
Pt100-2 4-wire FP Axxx -200.00 . +400.00 °C 0.01 K   ± 0.05 K   ZA 9030-FS2
Ni100 4-wire   -60.00 . +240.00 °C 0.1 K   ± 0,05 K   ZA 9030-FS3
NiCr-Ni (K) FT Axxx -200.0 . +1370.0 °C 0.1 K ± 0.05 K ± 0.05 % de v.m.. ZA 9020-FS
NiCroSil-Nisil (N)   -200.0 . +1300.0 °C 0.1 K ± 0.05 K ± 0,05 % de v.m. ZA 9020-FSN
Fe-CuNi (L)   -200.0 . +900.0 °C 0.1 K ± 0.05 K ± 0.05 % de v.m. ZA 9000-FSL
Fe-CuNi (J)   -200.0 . +1000.0 °C 0.1 K ± 0.05 K ± 0,05 % de v.m. ZA 9000-FSJ
Cu-CuNi (U)   -200.0 . +600.0 °C 0.1 K ± 0.05 K ± 0.05 % de v.m. ZA 9000-FSU
Cu-CuNi (T)   -200.0 . +400.0 °C 0.1 K ± 0.05 K ± 0,05 % de v.m. ZA 9000-FST
PtRh10-Pt (S)   -0.0 . +1760.0 °C 0.1 K   ± 0.3 K   ZA 9000-FSS
PtRh13-Pt (R)   0.0 . +1760.0 °C 0.1 K   ± 0,3 K   ZA 9000-FSR
PtRh30-PtRh6 (B)   +400.0 . +1800.0 °C 0.1 K   ± 0.3 K   ZA 9000-FSB
AuFe-Cr   -270.0 . +60.0 °C 0.1 K   ± 0,1 K   ZA 9000-FSA
Ntc Type N FN Axxx -50.00 . +125.00 °C 0.01 K   ± 0.05 K   ZA 9040-FS1
Signaux électriques:
Millivolt DC   -10.0 . +55.0 mV 1 uV   -   ZA 9000-FS0
Millivolt 1 DC   -26.0 . +26.0 mV 1 mV   -   ZA 9000-FS1
Millivolt 2 DC   -260.0 . +260.0 mV 0.01 mV   -   ZA 9000-FS2
Volt DC   -2.6 . +2.6 V 0.1 mV   -   ZA 9000-FS
Diff.-Milliampère DC U+=5V   -10.0 . +55.0 mV 1 mV   -   ZA 9050-FS0
Diff.-Milliampère1 DC U+=5V   -26.0 . +26.0 mV 1 mV   -   ZA 9050-FS1
Diff.-Milliampère2 DC U+=5V   -260.0 . +260.0 mV 0.01 mV   -   ZA 9050-FS2
Diff.-Volt DC U+=5V   -2.6 . +2.6 V 0.1 mV   -   ZA 9050-FS
Milliampère DC   -32.0 . +32.0 mA 1 mA   -   ZA 9601-FS1
Pourcentage (4-20mA DC)   0.0 . 100.0 % 0.01 %   -   ZA 9601-FS2
Ohm   00.0 . 50.00 Ohm 0.01 Ohm   -   ZA 9003-FS
Fréquence   0 . 25000 Hz 1 Hz   -   ZA 9909-AK1
Impulsions/Cycles   0 . 65000       -   ZA 9909-AK2
Sondes infrarouges:
Infrarouge 1 FI A628-1/5 0.0 . + 200.0 °C 0.1 K ± 0.05 K ± 0.05 % de v.m. ZA 9008-FS1
Infrarouge 2 FI A628-2 0.0 . + 800.0 °C 0.1 K ± 0.4 K     ZA 9008-FS2
Infrarouge3 FI A628-3 - 30.0 . + 70.0 °C 0.1 K ± 0.05 K     ZA 9008-FS3
Infrarouge 4 FI A628-4 - 30.0 . + 100.0 °C 0.1 K ± 0.05 K     ZA 9008-FS4
Infrarouge 6 FI A628-6 0.0 . + 500.0 °C 0.1 K ± 0.1 K ± 0.05 % de v.m. ZA 9008-FS6
Sondes d'humidité:
  FH A646   ZA 9046-FS
Rel. humidité   0 . 100.0 %H 0.1 %   -    
Point de rosée   - 25.0 . + 100.0 °C 0.1 K ± 0.2 K      
Rapport de mélange   0.0 . 500.0 g/kg 0.1 g/kg   ± 0.5 % de v.m.  
Pression de vapeur partielle   0.0 . 1013.2 mbar 0.1 mbar ±0.1mbar ± 0.1 % de v.m.  
enthalpie   0.0 . 400.0 kJ/kg 0.1 kJ/kg   ± 0.5 % de v.m.  
Psychrometers:
  FN A846   ZA 9846-AK
Température sèche   0.0 . + 125.0 °C 0.01 K ± 0.05 K      
Température humide   0.0 . + 100.0 °C 0.01 K ± 0.05 K      
rel. humidité   0.0 . 100.0 %H 0.1 %     ± 1.0 %H  
Point de rosée   - 25.0 . + 100.0 °C 0.1 K ± 0.2 K      
Rapport de mélange   0.0 . 500.0 g/kg 0.1 g/kg   ± 0.5 % de v.m.  
Vapeur de pression partielle   0.0 . 1013.2 mbar 0.1 mbar ± 0.1mbar ± 0.1 % de v.m.  
enthalpie   0.0 . 400.0 kJ/kg 0.1 kJ/kg   ± 0.5 % de v.m.  
Anémomètres:
Hélice normal FV A915-S120 0.30 . 20.00 m/s 0.01 m/s ± 0.1 m/s ± 0.2 % de v.m. ZA 9915-AKS1
Hélice normal FV A915-S140 0.40 . 40.00 m/s 0.01 m/s ± 0.2 m/s ± 0.2 % de v.m. ZA 9915-AKS2
Hélice micro FV A915-S220 0.50 . 20.00 m/s 0.01 m/s ± 0.1 m/s ± 0.2 % de v.m. ZA 9915-AKS3
Hélice micro FV A915-S240 0.60 . 40.00 m/s 0.01 m/s ± 0.2 m/s ± 0.2 % de v.m. ZA 9915-AKS4
Hélice micro FV A915-MA1 0.10 . 20.00 m/s 0.01 m/s ± 0.1 m/s ± 0.2 % de v.m. ZA 9915-AK5
Turbine hydrolique FV A915-WM1 0.00 . 5.00 m/s 0.01 m/s ± 0.1 m/s ± 0.2 % de v.m. ZA 9915-AK6
Capt. tube Pilot FD A612-M1 0.5 . 40.00 m/s 0.01 m/s ± 0.1 m/s      
Capt. tude Pilot FD A612-M6 1.8 . 90.00 m/s 0.01 m/s ± 0.1 m/s      
Autres capteurs de mesure (exemples):
Plaques de flux FQ Axxx - 260.0 . + 260.0 mV 0.01 mV   -   ZA 9007-FS
Sonde pour l'humidité des matériaux FH A696-MF 0 . 50.0 % 0.1 %   -    
Sonde Lux FL A613-VL 0 . 26000 lux 1 lux   -    
Sondes UV FL A613-UV 0 . 54 W/m² 2 W/m²   -    
Sondes radiométrique FL A613-RD 0 . 650 W/m² 30 W/m²   -    
    0 . 65 W/m² 3 W/m²   -    
    0 . 870 mW 40 mW   -    
    0 . 87 µ 4 µ   -    
Pression diff. FD A612-M1/S1 0 . 2000 Pa 0.1 Pa   -   ZA 9612-AKS1
Capteur de pression FD 9612-xx 0.0 . 1050.0 mbar 0.1 mbar   -    
Barometres FD A612-MA 0.0 . 20.0 bar 0.1 mbar   -   ZA 9012-AKx
Capteur de force FK Axxx 0.0 . 50.00 kN 0.01 kN   -    
tachometre FU A919-MF 0.0 . 6000 rpm 15 rpm   -    
thermoanemomètre FV A635-THx 0.0 . 10.00 m/s 0.001 m/s   -    
Sonde PH FY A8PH-Ex 0.0 . 14.00 pH 0.01 pH   -   ZA 9610-AKY
Sonde Redox FY A8RX-Ex 0.0 . 2600.0 mV 0.1 mV   -   ZA 9610-AKY
Sonde de conductivité FY A641-LF 0.0 . 20.000 mS 0.001 mS ± 0.05 mS ± 1 % of m.v.  
Sonde de conductivité FY A641-LF2 5.0 . 200.0 µ 0.1 µ ± 0.5 µ ± 2 % of m.v.  
Sonde CO2 FY A600-CO2 5 . 25000 ppm <200 ppm   ± 1 % valeur finale  
Sonde O2 FY A600-O2 1 . 100 % 0.1 %   ± 1 % valeur finale  
Sonde CO FY A600-O 0 . 300 ppm <10 ppm   ± 3 % valeur finale  

{page précédente}